单项选择题
A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()
A.defective solenoid valve
B.dirty fuel nozzle
C.grounded high tension lead
D.faulty ignition cable connector
点击查看答案&解析
相关考题
-
单项选择题
A firebox explosion in an automatically fired auxiliary boiler may be the result of ()
A.excessive purging before lighting off
B.insufficient trail for ignition period
C.a faulty transformer in the ignition circuit
D.insufficient purging before lighting off -
单项选择题
The diesel engine exhaust gas bypass, as fitted with some waste heat boilers, is installed to ()
A.prevent engine back pressure at heavy loads
B.increase total engine efficiency at low loads
C.prevent boiler corrosion at low engine loads
D.improve engine fuel consumption at any load -
单项选择题
The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()
A.steam demand is high
B.salinity is high
C.safety valve simmers
D.burner flame is extinguished